 Upgrade from VisionFlow 7.2 to VisionFlow 7.2.1 Export knowledge base Export     SubscribeSubscribe      Show article info
First of all; take a backup copy of your current installation, including the database!

 

 Shut down your Tomcat server

 

 Again, make sure that you have made a backup of your Tomcat webapp (all files) and the database!

 

Knowledge Base Images/Icons/number_3_blue.gif Extract the content from 'vp_installed_v7.2.1_upgrade_from_v7.2-20110719.zip' over your current installation.

 

Knowledge Base Images/Icons/number_4_blue.gif Update your VisionFlow database by running the SQL script 'upgrade_from_v7.2_to_v7.2.1.sql' located in the directory: '/WEB-INF/internal_docs/installed version/db_scripts/v7.2.1/Upgrade from v7.2'. Choose the directory that match your database, MS SQL Server or MySQL.

 

Knowledge Base Images/Icons/number_5_blue.gif [OPTIONAL]

This section only applies if you have installed the chat module.

We denote the folder where you installed Tigase: tigase_root and the VisionFlow webapp direcory: vp_root. 

 

1. Edit tigase_root/etc/init.properties.

 

 Replace the line

--sm-plugins=-message,+message-all,+vp_history=2 

with:

--sm-plugins=-message,+vp_message_synch,+vp_history=2 

 

Add this in the end (used for authentication):

 

--webServiceUrl = http:///service/VisionFlow-v2/VisionFlowWebServiceService

 

 

2. Replace

tigase_root/libs/vp-tigase-addons-1.0.0.jar

with

vp_root/WEB-INF/internal_docs/installed version/configuration/chatmodule/vp-tigase-addons-1.0.0.jar

 

3. Restart Tigase.

 

4. If you are using the support chat module. You should update the scripts for the support chat with correct versions. See here.

 

 

 

 

 

 

 

 